| Device Type |
Define whether the supplier will manufacture femoral stems, femoral heads, acetabular shells, liners, or complete hip systems. |
Component list, implant configuration, laterality, modular interfaces, and size range. |
Approved product drawings and design specifications. |
Manufacturing scope, equipment list, sample drawings, and completed product questionnaire. |
Critical |
| Material Selection |
Select implant-grade metallic, ceramic, or polymer materials according to the approved design and intended articulation. |
Common examples include titanium alloy for stems, cobalt-chromium alloy for heads, stainless steel for selected components, ceramic for heads or liners, and highly cross-linked polyethylene for liners. |
ISO 5832 series, ASTM F75, ASTM F136, ASTM F90, ASTM F648, and applicable material specifications. |
Material certificates, heat or lot traceability, chemical analysis, mechanical test results, and supplier qualification records. |
Critical |
| Design Control |
Confirm the supplier can manufacture from controlled drawings, specifications, CAD files, and revision-managed documentation. |
Document revision, drawing tolerances, critical-to-quality characteristics, change-notification period, and design-transfer records. |
ISO 13485 design-transfer and document-control requirements. |
Document-control procedure, change-control workflow, design-transfer checklist, and sample inspection plan. |
Critical |
| Dimensional Capability |
Control implant geometry, taper interfaces, bore dimensions, thread features, mating surfaces, and size transitions. |
Tolerance limits must be taken from the approved drawing; typical controlled characteristics include taper angle, diameter, concentricity, roundness, and surface profile. |
Product drawing, GD&T requirements, calibrated measurement methods, and applicable implant standards. |
Capability studies, CMM reports, gauge calibration certificates, first-article inspection, and process-control plans. |
Critical |
| Surface Finish |
Define distinct surface requirements for articulating, porous, grit-blasted, polished, coated, and non-articulating areas. |
Specify Ra or other surface parameters by functional area; articulating surfaces generally require a significantly finer finish than fixation surfaces. |
ISO 7206 series, drawing requirements, and validated surface-measurement procedures. |
Surface roughness reports, visual standards, blasting or polishing parameters, coating records, and contamination-control results. |
Critical |
| Manufacturing Processes |
Match the supplier’s process capability to the selected material and geometry, including forging, casting, CNC machining, grinding, polishing, coating, cleaning, and packaging. |
Process route, machine capacity, batch size, cycle time, validated parameters, and subcontracted operations. |
Validated manufacturing processes and the approved device master record. |
Process flow chart, PFMEA, control plan, equipment qualification, operator training, and subcontractor controls. |
Critical |
| Mechanical Testing |
Verify fatigue strength, static strength, fixation performance, taper connection performance, and wear-related requirements where applicable. |
Test configuration, load levels, cycle counts, acceptance criteria, sample quantity, and failure assessment must be defined in the test protocol. |
ISO 7206 series for hip-joint prostheses and applicable ASTM test methods. |
Independent laboratory reports, validated test methods, raw data, deviation records, and corrective-action history. |
Critical |
| Biocompatibility and Cleanliness |
Control residues, particles, processing chemicals, endotoxins, and biological safety risks before packaging or sterilization. |
Cleaning validation, particulate limits, residue limits, bioburden or endotoxin requirements, and inspection frequency. |
ISO 10993 series, ISO 19227, ISO 11737 where applicable, and validated cleaning specifications. |
Cleaning-validation reports, laboratory results, environmental-monitoring records, and contamination-control procedures. |
Critical |
| Quality Management System |
Use a regulated medical-device quality system covering purchasing, production, inspection, nonconformance, CAPA, complaints, and traceability. |
Current certification status, audit scope, certificate expiry date, nonconformance rate, and CAPA closure performance. |
ISO 13485:2016 and applicable regulatory quality-system requirements. |
Valid certificate, latest surveillance-audit outcome, quality manual or summary, CAPA metrics, and audit-response records. |
Critical |
| Risk Management |
Ensure manufacturing risks are linked to product risks, process controls, inspection methods, and post-production monitoring. |
Risk-control linkage, severity and probability evaluation, residual-risk review, and process-FMEA coverage. |
ISO 14971:2019. |
Risk-management file inputs, PFMEA, control plan, complaint trends, and evidence of periodic risk review. |
Critical |
| Regulatory and Market Scope |
Define the intended sales regions and determine whether the supplier supports the required technical documentation and regulatory submissions. |
Target markets, device classification, registration pathway, labeling responsibility, and technical-file ownership. |
Applicable national medical-device regulations and market-specific submission requirements. |
Regulatory support experience, submission documentation samples, change-control commitments, and traceability records. |
High |
| Production Volume |
Align annual demand, launch quantities, minimum order quantities, and capacity expansion plans with the supplier’s available resources. |
Forecast quantity, pilot-lot quantity, annual capacity, lead time, safety stock, and capacity utilization. |
Commercial supply agreement and approved production plan. |
Capacity model, production schedule, equipment loading, labor plan, lead-time history, and business-continuity plan. |
High |
| Sterilization and Packaging |
Define whether the supplier provides non-sterile packaging, terminal sterilization, sterile-barrier packaging, or coordination with an approved sterilization provider. |
Sterilization method, packaging configuration, shelf-life target, seal-strength criteria, transport simulation, and integrity testing. |
ISO 11607, ISO 11135, ISO 11137, ISO 17665, and ISO 11737 where applicable. |
Packaging-validation reports, sterilization-validation records, seal tests, stability data, and distribution-simulation results. |
High |
| Traceability |
Maintain traceability from raw material and manufacturing batch through inspection, packaging, shipment, and complaint investigation. |
Lot or serial number structure, record-retention period, genealogy fields, and recall-readiness. |
ISO 13485 traceability and record-control requirements. |
Device-history-record sample, electronic traceability demonstration, retention policy, and mock-recall results. |
Critical |
| Supplier Evaluation Metrics |
Use objective metrics rather than price alone when comparing qualified manufacturing suppliers. |
On-time delivery, first-pass yield, nonconformance rate, complaint rate, CAPA closure time, audit findings, lead time, and total landed cost. |
Quality agreement, supplier scorecard, and periodic supplier-review procedure. |
At least 12 months of anonymized KPI data, customer-reference process, audit results, and corrective-action records. |
High |